BioChar King – BK-1000

The BioChar King BK-1000 is a 1 million BTU, Premium BioChar maker that can produce continuous streams of high-quality BioChar up to 20 gallons per hour from biomass such as woodchips. The BK-1000 is capable of 1,250,000 BTU continuous output, with automated computer controls, highly efficient and clean burn, and passes all safety standards for indoor and outdoor use.  The BK-1000 is essentially the same as the Bio-Burner model BB-1000 with the water heat exchanger removed in order to reduce cost in applications where hot water heat is not needed.

Technical Specifications

 

  
 
Heat Output
BioChar Output
Ash Removal
Gas Ignition & Backup
Fuel Bin Capacity
User Interface
Maximum Fuel Size
Acceptable Fuel Moisture
Water Temp Range
Flue Temp Range
Combustion Temp Range
Water Storage
Water Hookup
Water Pump
Water Flow Rate Required
Boiler Protection Valve
Weight
Power Requirement
Flue Pipe Size
Motor Controls
Heat Exchanger Turbulators
Length (ft)
Width (ft)
Height (ft)

BB-300

Heat Output : 300,000 BTU (88+kw) Continuous
BioChar Output : 7 gal. / hr
Ash Removal : Automatic/manual
Gas Ignition & Backup : Propane or Natural Gas 399K BTU input (1" NPT)
Fuel Bin Capacity : 2, 6,12, 18, or 24 Cubic Yard
User Interface : Touch screen controls with remote access capabilities.
Maximum Fuel Size : 2" Chip
Acceptable Fuel Moisture : Up to 40% MC (wet basis)
Water Temp Range : 135-185/205 ºF
Flue Temp Range : 250-450 ºF
Combustion Temp Range : 1100-1700 ºF
Water Storage : 88 Gallons
Water Hookup : 2" NPT
Water Pump : 50 GPM (included)
Water Flow Rate Required : 50 GPM (minimum)
Boiler Protection Valve : 135 Degree (included)
Weight : 2,900 LBS
Power Requirement : 220 VAC, 20 amps
Flue Pipe Size : 8"
Motor Controls : PLC Controlled VFD
Heat Exchanger Turbulators : External access for easy cleaning
Length (ft) : 4' 7"
Width (ft) : 9' 5"
Height (ft): 5' 9"

BB-500

Heat Output : 500,000 BTU (150+kw)
BioChar Output : 10 gal. / hr
Ash Removal : Automatic/manual
Gas Ignition & Backup : Propane or Natural Gas 399K BTU input (1" NPT)
Fuel Bin Capacity : 2, 6, 12, 18, or 24 Cubic Yard
User Interface : Touch screen controls with remote access capabilities.
Maximum Fuel Size : 2" Chip
Acceptable Fuel Moisture : Up to 40% MC (wet basis)
Water Temp Range : 135-185/205 ºF
Flue Temp Range : 250-450 ºF
Combustion Temp Range : 1100-1700 ºF
Water Storage : 134 Gallons
Water Hookup : 2" NPT
Water Pump : 50 GPM (included)
Water Flow Rate Required : 50 GPM (minimum)
Boiler Protection Valve : 135 Degree (included)
Weight : 3,500 LBS
Power Requirement : 220 VAC, 20 amps
Flue Pipe Size : 8"
Motor Controls : PLC Controlled VFD
Heat Exchanger Turbulators : External access for easy cleaning
Length (ft) : 4' 7"
Width (ft) : 9' 5"
Height (ft): 6' 11"

BB-1000

Heat Output : 1,250,000 BTU (366+kW)
BioChar Output : 20 gal. / hr
Ash Removal : Automatic/manual
Gas Ignition & Backup : Propane or Natural Gas 1.5MM BTU input
Fuel Bin Capacity : 6,12 ,18, or 24 Cubic Yard
User Interface : Touch screen controls with remote access capabilities.
Maximum Fuel Size : 2" Chip
Acceptable Fuel Moisture : Up to 40% MC (wet basis)
Water Temp Range : 135-185/205 ºF
Flue Temp Range : 250-450 ºF
Combustion Temp Range : 1100-1700 ºF
Water Storage : 350 Gallons
Water Hookup : 3" NPT
Water Pump : 100 GPM (included)
Water Flow Rate Required : 100 GPM (minimum)
Boiler Protection Valve : 135 Degree (included)
Weight : 8,000 LBS
Power Requirement : 220 VAC, 30 amps
Flue Pipe Size : 10"
Motor Controls : PLC Controlled VFD
Heat Exchanger Turbulators : External access for easy cleaning
Length (ft) : 7' 6"
Width (ft) : 15' 9"
Height (ft): 9' 3"

BK-1000

Heat Output : 1,250,000 BTU (366+kW)
BioChar Output : 20 gal. / hr
Ash Removal : Automatic/manual
Gas Ignition & Backup : Propane or Natural Gas 1.5MM BTU input
Fuel Bin Capacity : 6, 12, 18, or 24 Cubic Yard
User Interface : Touch screen controls with remote access capabilities.
Maximum Fuel Size : 2" Chip
Acceptable Fuel Moisture : Up to 40% MC (wet basis)
Water Temp Range : N/A
Flue Temp Range : 250-450 ºF
Combustion Temp Range : 1100-1700 ºF
Water Storage : N/A
Water Hookup : N/A
Water Pump : N/A
Water Flow Rate Required : N/A
Boiler Protection Valve : 135 Degree (included)
Weight : 4,000 LBS
Power Requirement : 220 VAC, 30 amps
Flue Pipe Size : 10"
Motor Controls : PLC Controlled VFD
Heat Exchanger Turbulators : N/A
Length (ft) : 7' 6"
Width (ft) : -
Height (ft): 9' 3"